Hotjet ZETXe Heat Pump
- Type: Air-to-water
- Installation: Outdoor (External)
- Heat loss: Up to 20 kW
- Power variants: 7, 10, 15 kW
- Regulation: Inverter (variable speed)
- Control: SIEMENS (3 heating/cooling circuits)
- Cascade: Yes
- Defrosting: Reverse cycle
HOTJET ZETXe – outdoor inverter monoblock
Our best-selling series. The ZETXe sits outside, connects to the house with two pipes and one cable – and heats. The inverter adjusts output smoothly to match demand, so the unit never runs at full power unnecessarily.
The standard configuration controls up to 3 circuits (heating, cooling, DHW). Copeland scroll compressor with variable speed.
Why ZETXe
- Inverter regulation – smooth operation, lower consumption, longer compressor life
- 3 circuits included – heating, cooling and hot water at no extra cost
- Cascade – need more output? Connect multiple units together
- Active noise suppression – noise reduction system for peaceful neighbourhood
- Reverse cycle defrosting – efficient and fast
Power Variants
| Model | Building heat loss | Heating output A7/W35 |
|---|---|---|
| ZETXe-7 | 4–7 kW | 6.25 kW (COP 5.10) |
| ZETXe-10 | 5–15 kW | 8.04 kW (COP 5.02) |
| ZETXe-15 | 10–20 kW | 10.29 kW (COP 5.03) |
Included in Delivery
- Heat pump (heating + cooling)
- Siemens control (3 circuits)
- Electric boiler 7.5 kW
- Circulation pump
- Webserver + app for iOS/Android
ZETXe vs. ZETXi
ZETXe (External) sits outside. ZETXi (Internal) is installed indoors with air supplied through ducts. Technically identical – they differ only in installation method. ZETXi is quieter for the surroundings, ZETXe takes up less space inside.
| Type | Air-to-water |
|---|---|
| Installation | Outdoor (External) |
| Heat loss | Up to 20 kW |
| Power variants | 7, 10, 15 kW |
| Regulation | Inverter (variable speed) |
| Control | SIEMENS (3 heating/cooling circuits) |
| Cascade | Yes |
| Defrosting | Reverse cycle |
| ZETXe | 7 ZETXe | 10 ZETXe | 15 ZETXe |
|---|---|---|---|
| Compressor | Copeland Scroll Variable Speed | ||
| Models | 7 ZETXe / 10 ZETXe / 15 ZETXe | ||
| Suitable for heat losses | 4–7 kW | 5–15 kW | 10–20 kW |
| Output min/max for 25–120 Hz (A2/W35) | 1.8–9 kW | 2.6–13 kW | 4–20 kW |
| Heating output / COP A7/W35 (60 Hz) | 6.25 kW / 5.10 | 8.04 kW / 5.02 | 10.29 kW / 5.03 |
| Heating output / COP A2/W35 (60 Hz) | 4.33 kW / 4.09 | 6.35 kW / 4.04 | 8.33 kW / 4.11 |
| Heating output / COP A-7/W50 (120 Hz) | 8 kW | 11 kW | 17 kW |
| Sound power LWA A7/W35 | 52 dB | 53 dB | 54 dB |
| Energy class (with regulator) | A+++/A++ | ||
| Weight | 175 kg | 180 kg | 185 kg |
| Dimensions (w × d × h) | 1270 × 600 × 1185 mm | ||
| SVT code for subsidies | SVT31191 | SVT31192 | SVT31194 |